Skip to main content

Overview of JCB2LE-80M4P+A 4 Pole RCBO With Alarm 6kA Safety Switch

The JCB2LE-80M4P+A is the latest residual current circuit breaker with overload protection, providing the next-generation features to upgrade electrical safety in both industrial and commercial installations and residential premises. Using high-tech electronic technology, this product guarantees effective protection against earth faults and overloads for the protection of equipment and people.

1

The RCBO has a breaking capacity of 6kA and is current-rated up to 80A, although options start for as low as 6A. They are designed to meet the latest international standards, including IEC 61009-1 and EN61009-1, and as such, can be installed in consumer units and distribution boards. This versatility is further emphasized by the fact that both Type A and Type AC variants are available to suit different electrical needs.

Key Features and Benefits

1. Dual Protection Mechanism

The JCB2LE-80M4P+A RCBO combines residual current protection with overload and short circuit protection. This dual mechanism ensures full-scale safety from electrical faults, considerably reducing probabilities of electrical shock and fire hazards, hence forming an indispensable part of any electrical installation.

2. High Breaking Capacity

Equipped with a breaking capacity of 6kA, this RCBO handles high fault currents effectively to ensure that circuits are rapidly disconnected in case a fault occurs. This ability is, therefore, very important in terms of the prevention of damage to electrical systems and enhancing general safety both in domestic and commercial settings.

3. Adjustable Tripping Sensitivity

It provides tripping sensitivity options of 30mA, 100mA, and 300mA, thereby enabling one to use these options in selecting the kind of protection that a user deems fit. Such kinds of customizations will ensure that the RCBO is able to respond to fault conditions effectively and different ways to enhance safety and reliability.

4. Easy Installation and Maintenance

The JCB2LE-80M4P+A has insulated openings for ease of busbar connections and accommodates standard DIN rail mounting. Hence, its installation is easy; this reduces the time taken for such a setup and, therefore, minimizes maintenance. It is a very feasible package for electricians and installers.

5. International Standards Conformity

This RCBO follows the strict standards of IEC 61009-1 and EN61009-1, hence ensuring reliability and safety for a wide field of applications. The meeting of these tight requirements raises users’ and installers’ confidence in attesting to the fact that the device is suitable for industrial, commercial, and residential applications.

Technical Specification

The technical specifications bring out the strong structure and operating specifications of the JCB2LE-80M4P+A. The rated voltage is specified to be 400V to 415V AC. The devices work with different kinds of loads and thus find their applications in various fields. The insulation voltage of the device is 500V and that means high voltages would not affect its safe operation.

The 10,000 operations for the mechanical life and 2,000 operations for the electrical life of the RCBO show how durable and reliable the device will be in the long run. The protection degree of IP20 protects it well against dust and moisture, thus being suitable for indoor mounting. Besides this, the ambient temperature within -5℃~+40℃ offers ideal working conditions for JCB2LE-80M4P+A.

2

Applications and Use Cases

1. Industrial Applications

The JCB2LE-80M4P+A RCBO is integrally important in the area of industrial application for machinery and equipment protection against electrical faults. High currents handled and overload protection features go a long way to guarantee the safety of operations, limiting equipment damage and downtime due to electrical failures.

2. Commercial Buildings

For commercial buildings, RCBOs come in handy because they protect electrical installations from earth faults and overload. They assure reliability in circuit protection to avoid possible dangers such as electrical fire that increases safety among employees and customers within retail spaces and offices.

3. High-Rise Buildings

The JCB2LE-80M4P+A protects complex electrical systems in high-rise buildings. Its compact design and high breaking capacity come in useful since this unit can be installed in distribution boards. All the floors would be provided with safe and reliable electrical service while fully complying with the related safety regulations.

4. Residential Use

RCBOs have enhanced safety for residential applications by protecting the home against electric shock and fire hazards. The alarm feature provides the possibility of quick intervention in case something might be wrong. This will grant a safe living environment, in moist areas specifically.

5. Outdoor Installations

The JCB2LE-80M4P+A is also designed for outdoor applications such as illumination in the garden and electric vehicle charging stations. With a solid construction and protection rating IP20, this device can resist environmental challenges outdoors when there is a possibility of moisture and dirt exposure, offering effective electrical safety.

Installation and Maintenance

1. Preparation

First, check that the supply to the circuit the RCBO is installed in is switched off. Check there is no electrical current using a voltage tester. Prepare the tools: screwdriver and wire strippers. Ensure the JCB2LE-80M4P+A RCBO is suitable for your installation requirements.

2. Mounting the RCBO

The unit should be installed on a standard 35mm DIN rail by engaging it with the rail and pressing down until it clicks securely in place. Correctly position the RCBO for easy access to the terminals for wiring.

3. Wiring Connections

Connect the incoming line and neutral wires to the respective terminals of the RCBO. The line normally goes to the top, while neutral goes to the bottom. Ensure that all connections are tight and snug at a torque of 2.5N.m recommended.

4. Device Testing

Once the wiring has been completed, return power to the circuit. Test the RCBO with the test button provided on it for whether it works appropriately. The indicator lights should show green for OFF and red for ON, which would indeed confirm that the device is working.

5. Regular Maintenance

Schedule periodic checks on the RCBO to stay in good working condition. Check for any signs of wear and damage; periodic testing of its functionality, tripping properly under faulty conditions. It will improve safety and reliability.

The JCB2LE-80M4P+A 4 Pole RCBO With Alarm 6kA Safety Switch Circuit Breaker provides complete earth fault and overload protection for the modern electrical installation. Its robust design, combined with advanced features and compliance with international standards, makes it reliable across applications, including industrial to residential installations. The JCB2LE-80M4P+A is a worthy investment that would raise the bar high in safety considerations for the protection of persons and properties from electrical hazardous occurrences. Ease of installation and maintenance further cements it as one of the pioneering solutions in the field of electrical safety devices.

Media Contact
Company Name: Wenzhou Wanlai Electric Co., Ltd
Email: Send Email
Phone: +86 15706765989
Country: China
Website: https://www.jiuces.com/

Stock Quote API & Stock News API supplied by www.cloudquote.io
Quotes delayed at least 20 minutes.
By accessing this page, you agree to the following
Privacy Policy and Terms and Conditions.